(ASCEND) Data filter/performance problem
A Windows 95 user with a modem dials into our MAX 4004 (5.0Ap1) and uses
IBM's Client Access to get to their AS/400 (using IP). If I use the RADIUS
profile below without any data filters, the connection to the AS/400 is very
quick, only a few seconds to connect:
johndoe Password = "ACE", Ascend-Token-Immediate = 1
User-Service = Framed-User,
Framed-Protocol = PPP,
Ascend-Route-IP = Route-IP-Yes,
Ascend-Route-IPX = Route-IPX-No,
Ascend-Idle-Limit = 28800
However, I would prefer to limit them with access only to the AS/400. So I
added this:
Ascend-Data-Filter = "ip in forward dstip 157.239.20.250/32"
With this filter in, the connection to the AS/400 takes more than 3 minutes.
Ping, telnet, and everything else work fine. A sniffer on the LAN showed
little traffic, so apparently something is happening between the client and
the MAX.
Any recommendations on how to troubleshoot something like this on the MAX?