RE: (ASCEND) Silence on connect.
At 04:41 PM 11/11/97 -0000, Peter Galbavy wrote:
>On 11 November 1997 15:48, Rick Wagner [SMTP:wagner@fuse.net] wrote:
>> We are getting several reports of users connecting to our Max's and
>> receive dead air, no modem tones nothing. In most cases I have 4000's or
>> 4004's with 48/72 modems, and 48/72 CT1's. During my peak times the boxes
>> are getting slammed with calls as soon as 1 drops the channel is grabbed
>> with a new call. Is it possible that the Max is not able to reset the
>> modems or react quick enough to route the call to a modem? I am running
>> Ap27 on all but 4 boxes, and will be up to Ap33 next Monday. Does anyone
>> have any ideas? I remember a thread a few weeks ago about the TNT, can it
>> handle 288 calls or is that a problem also (running 1.3Ap2)?
>
>This problem was fixed for us on the TNT some time back. TR#2662 I believe.
>This only affected k56 cards. The modems were not being given enough time to
>reset.
I think it was TR#2685.... TR#2662 is related to the V.8bis tone tripping up
some 14,400 modems.
Which version are you running now (TNT that is)?