Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Silence on connect.



At 08:08 AM 11/13/97 -0000, Peter Galbavy wrote:
>>I think it was TR#2685.... TR#2662 is related to the V.8bis tone tripping
>up
>>some 14,400 modems.
>>
>>Which version are you running now (TNT that is)?
>
>Oops - wrong bit of the white board. We are on engineering code. People on
>this list really do not want that - yet.

Aha....and those fixes should be in the next TNT patch release.

>PS Reading between the lines of a mail with one of the engineers - if you do
>not need to do coredumps etc (if this is meaningless then you don't) then
>make sure you have no profiles under "DEBUG". These can is some limited
>circumstances force a resetting modem card to stay down (for debugging of
>course) :(

Unless you're in 'debug' mode (spiritually that is ;), this most likely will
not be meaningful....


Kevin


++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: