Once upon a time Bench shaped the electrons to say...
>Can Max 4060 support BRI connections even if I don't have ISDN
>BRI network cards for it?  If yes, then how do I configure it?

BRI is a physical interface.  You can't use BRI without a BRI card to
plug into.

BRI is just one physical interface for ISDN, PRI is another.  If you 
really mean can a customer place a call from an ISDN call from a BRI
into a MAX - yes, the MAX terminates it on PRI.

>Would it be just setting the proper signal to ISDN? Currently
>we are using R2 signaling mode for an E1 line, we have one more

You can temrinate ISDN DOSBS calls on channellized T1, but off hand I'm
not sure if you can do ISDN into an R2 E1 line...

-MZ
--