Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) TNT power supplies
>From: Tim Seibert <seibertt@supernet.com>
>
> I've got a TNT that only has one high output supply in it. I've got a
>second one to install in it, but can't find any documentation to say
>whether the supplies are hot swappable. I did find in the manual where
>they are NOT hot swappable if there is an existing standard supply, but
>nothing is said about just adding a second supply when the original is a HO
>one. I think it would be extremely lame if the box had to be powered down
>to replace a malfunctioning supply. Will I need to power down the box (and
>make 668+ customers very angry), or can I just install this second supply
>without any down time.
They're hot-swappable, as is everything in a TNT except the shelf
controller and memory cards.
--
Peter Lalor Infoasis
plalor@infoasis.com http://www.infoasis.com/
"Where's my burrito?" -- Homer
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>