Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Re: NAS-Port-Type
At 11:58 AM 11/20/97 -0800, you wrote:
>>>>left out of the users file but we'd like to be able to restrict modem
users
>>>>to modems and ISDN to ISDN.
>>>
>>>What is your check-item set to in RADIUS?
>>>
>>>I would expect you need:
>>>
>>>NAS-Port-Type = ISDN-Sync
>>>
>>Yep, that's it... and that's what has me puzzled. I thought it must be a
>>config problem on my part but...
>
>Is ths MAX on a PRI or CT1 line ? Have you tried instead:
It on a PRI...
>
>NAS-Port-Type = Sync
>
>Which I guess would be the case for non-ISDN lines, as a CT1 may not be able
>to discriminate.....I'll look into what is supposed to be the difference
>between "Sync" and "ISDN-Sync"....
>
>>It finally accepted the NAS-Port-Type once I put User-Service on the first
>>line and NAS-Port-Type on the second line.... but shouldn't it keep the
>>customer from dialing in on a modem when the NAS-Port-Type is set to
>>ISDN-Sync?
I'll give it a whirl!
>
>Only when set as a check-item on the first line. Putting it on line 2 has no
>real effect.
>
OK, so I'm still learning!
Thanks, David