Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) MAX-4000 and Alcatel E-10 with R2 signalling?





Have you checked how many digits the Alcatel switch is sending to the
MAX ? You have to set that on parameter "# Complete", under
Net/E1->Line Config->.... Also, the phone number that you set for the
modem cards must match that number of digits. For example, if the
phone number is 9876543, but the switch sends only the last four
digits, then you must configure the phone number as 6543.



Regards,

-- 
+----------------------------------------------------------------------+
 Andre Novaes Cunha		|| Andre.Cunha@br.global-one.net 
 Systems Engineer		|| Global One Communications 
+----------------------------------------------------------------------+

> X-Authentication-Warning: max.bungi.com: majordom set sender to owner-ascend-users using -f
> X-ROUTED: Thu, 27 Nov 1997 21:48:22 +0800
> Date: Thu, 27 Nov 1997 21:52:51 +0800
> From: Balgansuren Batsukh <mis-mtc@magicnet.mn>
> Reply-To: mis-mtc@magicnet.mn
> Organization: Mongolian Telecommunictions Company
> Sender: owner-ascend-users@max.bungi.com
> Precedence: bulk
> Content-Type: text/plain; charset=us-ascii
> Content-Length: 1307
> 
> Hi!
> 
> I have a serious problem right now. My task is to force the MAX-4000 to
> answer the incoming calls coming from Alcatel E-10 switch.
> The problem is that we can use only the R2 signaling in E1 trunks
> between MAX and E-10. Now the MAX can see the trunks. It shows the good
> state of E1 lines (all dashes in status window, 's' mark for signaling
> (16th) time slot and 'LA' status). But any call from the external
> phone/modem cannot be done into the MAX.
> 
> And is to send the 'B6' signal which gives the switch the 'Subscriber
> is available' state, and therefore the switch can initiate the 'open
> line' state. BUT MAX DOESN'T RESPOND ANYTHING after the receiving the
> first digit of the called number! Then returns the 'inter-station busy'
> tone to the handset.
> I've tried the different setups in Alcatel and MAX4000 (and MAX has a
> few parameters in E1 line profile). Nothing could I change :-((
> 
> Has anybody tested the same configuration (MAX4000 and Alcatel E-10 with
> R2)? Can it work? Please help me, if you can!
> 
> Thanks,
> Balgansuren Batsukh, Expert Engineer
> Mongolian Telecommunications Company
> http://www.magicnet.mn/mtc
> Phone: 976-1-311131
> Fax: 976-1-325412
> 
> 
> ++ Ascend Users Mailing List ++
> To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd:	<http://www.nealis.net/ascend/faq>
> 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>