Re: (ASCEND) Question on Multi-Tech proxy server and Ascend MAX



At 11:50 AM 9/18/98 , Llabona, Nelson wrote:
>Have any of you used the MULTI-TECH Proxy Server 200-Series ?
>
>The Proxy server has 3 embedded 56k-flex modems.
>If I use one modem connection, PPP, everything works great.
>
>BUT, if I enable "MLPPP" on the proxy server transfers slow to a crawl
>or cease, even if I only use one modem.
>
>I've tried enableing 2 modems and MLPPP on the proxy server,
>and my RADIUS account is set to Framed-Protocol = MP.
>I tried MPP, same behavior.
>
>Any ideas ?
>
>BTW, the two modems do connect, data transfer just blows.

Are you using a farily recent software load on the MAXen? I've seen a couple
of reports recently on this list that people are getting analog MP connections
that work pretty well - so it might be a revision issue?

Are the data transfers that you refer to "crawling" from the MAX to the
MT, or the other way around?


Kevin Smith			(kevin@ascend.com)
Ascend Communications...